Wiring methods for pool pump motors are in 680 21 a.
Double insulated pool pump.
There s some possibility that a double insulated motor which didn t have a bonding jumper installed might be replaced by a motor that isn t double insulated resulting in a noncompliant installation.
Radiant pools offer greater structural integrity limitless installation options incredible warranty protection and energy savings that.
For more information on storable pools please refer to the storable pool article.
This pool may even be just plugged into an outside weatherproof gfi protected dwelling receptacle designed for general use.
Nec article 680 30 that s it.
Radiant pools are only sold through our network of radiant pools authorized dealers.
If your pump and filter sits up against a wall you only have to build 3 sides to your enclosure along with a hinged lid or front access door panels.
Our pool pump cover ideas have a patent design that encompasses a durable acoustic vinyl with a mass loaded vinyl combined with 3 8 closed cell acoustic dampening foam.
The only structural insulated swimming pool in the industry.
Nec article 680 part c the pool pump of a storable pool must be a listed double insulated pool pump motor.
When replacing the motor the installer must bond the new motor to the metal water piping system.
It acts both as a sound absorber and resistor to any sound pollution.
680 21 b provides the requirements for cord and plug connected double insulated pool motors.
A listed cord and plug connected pool pump incorporating an approved system of double insulation that provides a means for grounding only the internal and nonaccessible noncurrent carrying metal parts of the pump shall be connected to any wiring method recognized in chapter 38 that is suitable for the location.
Pool box hiding unsightly pool pumps and filters is the main purpose of a pool equipment box but it also protects pipes and pumps from rain snow sun and downed tree branches.